|
cell applications inc
102-3d 102 3d, supplied by cell applications inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/102-3d/product/cell applications inc Average 93 stars, based on 1 article reviews
102-3d - by Bioz Stars,
2026-06
93/100 stars
|
Buy from Supplier |
|
Modus Medical Devices Inc
phantom: modusqa mri3d Phantom: Modusqa Mri3d, supplied by Modus Medical Devices Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/phantom: modusqa mri3d/product/Modus Medical Devices Inc Average 90 stars, based on 1 article reviews
phantom: modusqa mri3d - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Siemens AG
3d geometric distortion correction 3d Geometric Distortion Correction, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/3d geometric distortion correction/product/Siemens AG Average 90 stars, based on 1 article reviews
3d geometric distortion correction - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Modus Medical Devices Inc
lightweight magnetic resonance imaging distortion in 3d phantom mrid 3d ![]() Lightweight Magnetic Resonance Imaging Distortion In 3d Phantom Mrid 3d, supplied by Modus Medical Devices Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/lightweight magnetic resonance imaging distortion in 3d phantom mrid 3d/product/Modus Medical Devices Inc Average 90 stars, based on 1 article reviews
lightweight magnetic resonance imaging distortion in 3d phantom mrid 3d - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Philips Healthcare
3d geometric distortion phantom ![]() 3d Geometric Distortion Phantom, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/3d geometric distortion phantom/product/Philips Healthcare Average 86 stars, based on 1 article reviews
3d geometric distortion phantom - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
Verlag GmbH
2d-mfi zeolites ![]() 2d Mfi Zeolites, supplied by Verlag GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/2d-mfi zeolites/product/Verlag GmbH Average 90 stars, based on 1 article reviews
2d-mfi zeolites - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Polytec Inc
polytec clv 3d compact 3 d ![]() Polytec Clv 3d Compact 3 D, supplied by Polytec Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/polytec clv 3d compact 3 d/product/Polytec Inc Average 86 stars, based on 1 article reviews
polytec clv 3d compact 3 d - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
3-D Matrix
3d platform ![]() 3d Platform, supplied by 3-D Matrix, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/3d platform/product/3-D Matrix Average 86 stars, based on 1 article reviews
3d platform - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
GFMesstechnik GmbH
primos 3d imaging ![]() Primos 3d Imaging, supplied by GFMesstechnik GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/primos 3d imaging/product/GFMesstechnik GmbH Average 90 stars, based on 1 article reviews
primos 3d imaging - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
3-D Matrix
3d matrix transpositions ![]() 3d Matrix Transpositions, supplied by 3-D Matrix, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/3d matrix transpositions/product/3-D Matrix Average 86 stars, based on 1 article reviews
3d matrix transpositions - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
3-D Matrix
dimensional 3d matrix ![]() Dimensional 3d Matrix, supplied by 3-D Matrix, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/dimensional 3d matrix/product/3-D Matrix Average 86 stars, based on 1 article reviews
dimensional 3d matrix - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
3-D Matrix
3d matrix model ![]() 3d Matrix Model, supplied by 3-D Matrix, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/3d matrix model/product/3-D Matrix Average 86 stars, based on 1 article reviews
3d matrix model - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of Applied Clinical Medical Physics
Article Title: System‐dependent image distortion related to gantry positions of a 0.35 T MRgRT: Characterization and the corresponding correction
doi: 10.1002/acm2.13826
Figure Lengend Snippet: (a) The sagittal view of the MRID 3D phantom with the onboard distortion correction turned (i) Off (DstOff) and (ii) On (DstOn) and (b) the axial view of the Fluke phantom with (i) DstOff and (ii) DstOn. In the Fluke phantom, the circular dots indicate the distortion analysis regions for the phantom and the blue and orange arrows indicate the 175 and 100 mm radius analysis regions, respectively.
Article Snippet: Recently, Lewis et al. used the
Techniques:
Journal: Journal of Applied Clinical Medical Physics
Article Title: System‐dependent image distortion related to gantry positions of a 0.35 T MRgRT: Characterization and the corresponding correction
doi: 10.1002/acm2.13826
Figure Lengend Snippet: MRID 3D phantom images mean and the maximum (Max) geometric distortion error for DstOff original and resampled images at all gantry angles
Article Snippet: Recently, Lewis et al. used the
Techniques:
Journal: Journal of Applied Clinical Medical Physics
Article Title: System‐dependent image distortion related to gantry positions of a 0.35 T MRgRT: Characterization and the corresponding correction
doi: 10.1002/acm2.13826
Figure Lengend Snippet: MRID 3D phantom images mean and the maximum geometric distortion error for DstOn original and resampled images at all gantry angles
Article Snippet: Recently, Lewis et al. used the
Techniques:
Journal: Journal of Applied Clinical Medical Physics
Article Title: System‐dependent image distortion related to gantry positions of a 0.35 T MRgRT: Characterization and the corresponding correction
doi: 10.1002/acm2.13826
Figure Lengend Snippet: Mean distortion using MRID 3D phantom. The mean distortion values of the original and resampled images on the right–left (RL), anterior–posterior (AP), and superior–inferior (SI) directions across all gantry angles. Plots show the values of (a) distortion correction off (DstOff) with distortion correction off resampled (DstOff (R)) and (b) distortion correction on (DstOn) with distortion correction on resampled (DstOn(R)).
Article Snippet: Recently, Lewis et al. used the
Techniques:
Journal: Journal of Applied Clinical Medical Physics
Article Title: System‐dependent image distortion related to gantry positions of a 0.35 T MRgRT: Characterization and the corresponding correction
doi: 10.1002/acm2.13826
Figure Lengend Snippet: Isocenter shift using MRID 3D phantom. The MRI isocenter distance to agreement (DTA) original and resampled for the (a) right–left (RL), (b) anterior–posterior (AP), and (c) superior–inferior (SI) directions across all gantry angles. Each plot includes the value for the distortion correction turned on (DstOn) and off (DstOff) for original images and DstOn(R), DstOff(R) for resampled images.
Article Snippet: Recently, Lewis et al. used the
Techniques:
Journal: Journal of Applied Clinical Medical Physics
Article Title: System‐dependent image distortion related to gantry positions of a 0.35 T MRgRT: Characterization and the corresponding correction
doi: 10.1002/acm2.13826
Figure Lengend Snippet: The axial view of the human chest MR image acquired at gantry 300° showing the original image and resampled image using the extended DVF generated from the MRID 3D phantom. The images are shown with the onboard Siemens distortion correction function turned on (DstOn) and turned off (DstOff). The dotted blue square box indicates the overlayed original and resampled images. In the overlay images, the primary image (DstOn) upper color is shown in white, and the secondary image (DstOff) upper color is shown in light brown.
Article Snippet: Recently, Lewis et al. used the
Techniques: Generated